| FVXG25K2V1B / RXG25K3V1B | FVXG25K2V1B / RXG25K2V1B | FVXG35K2V1B / RXG35K2V1B | FVXG35K2V1B / RXG35K3V1B | FVXG50K2V1B / RXG50K2V1B | FVXG50K2V1B / RXG50K3V1B | ||||
|---|---|---|---|---|---|---|---|---|---|
| Kapaciteti ftohës | Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | |
| Maks. | kW | 3.0 | 3.0 | 3.8 | 3.8 | 5.6 | 5.6 | ||
| Nom. | kW | 2.5 (2) | 2.5 (3) | 3.5 (3) | 3.5 (2) | 5.0 (3) | 5.0 (2) | ||
| Lidhjet e tubacioneve | Lëngu | Dia. jasht. | mm | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 |
| Gazi | Dia. jasht. | mm | 9.5 | 9.5 | 9.5 | 9.5 | 12.7 | 12.7 | |
| Kullimi | Diametri i jashtëm | mm | 18 | 18 | 18 | 18 | 18 | 18 | |
| Efikasiteti nominal | Konsumi vjetor i energjisë | kWh | 275 | 275 | 475 | 475 | 760 | 760 | |
| EER | 4.55 | 4.55 | 3.68 | 3.68 | 3.29 | 3.29 | |||
| COP | 4.36 | 4.36 | 3.72 | 3.72 | 3.67 | 3.67 | |||
| Direktiva e etiketimit të energjisë | Ftohje | A | A | A | A | A | A | ||
| Ngrohje | A | A | A | A | A | A | |||
| Kapaciteti ngrohës | Nom. | kW | 3.4 (3) | 3.4 (4) | 4.5 (4) | 4.5 (3) | 5.8 (4) | 5.8 (3) | |
| Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | ||
| Maks. | kW | 4.5 | 4.5 | 5.0 | 5.0 | 8.1 | 8.1 | ||
| Shënime | (1) - EER/COP sipas Eurovent 2012, vetëm për përdorim jashtë BE-së | (1) - Etiketa e energjisë: nga shkalla A (më efikasja) deri në G (më pak efikasja) | (1) - Etiketa e energjisë: nga shkalla A (më efikasja) deri në G (më pak efikasja) | (1) - EER/COP sipas Eurovent 2012, vetëm për përdorim jashtë BE-së | (1) - Etiketa e energjisë: nga shkalla A (më efikasja) deri në G (më pak efikasja) | (1) - EER/COP sipas Eurovent 2012, vetëm për përdorim jashtë BE-së | |||
| (2) - Ftohje: temp. e brendshme 27°CDB, 19°CWB; temp. e jashtme 35°CDB, 24°CWB | (2) - Konsumi vjetor i energjisë: bazuar në përdorimin mesatar prej 500 orë pune në vit me ngarkesë të plotë (kushte nominale). | (2) - Konsumi vjetor i energjisë: bazuar në përdorimin mesatar prej 500 orë pune në vit me ngarkesë të plotë (kushte nominale). | (2) - Ftohje: temp. e brendshme 27°CDB, 19°CWB; temp. e jashtme 35°CDB, 24°CWB | (2) - Konsumi vjetor i energjisë: bazuar në përdorimin mesatar prej 500 orë pune në vit me ngarkesë të plotë (kushte nominale). | (2) - Ftohje: temp. e brendshme 27°CDB, 19°CWB; temp. e jashtme 35°CDB, 24°CWB | ||||
| (3) - Ngrohje: temp. e brendshme 20°CDB; temp. e jashtme 7°CDB, 6°CWB | (3) - Ftohje: temp. e brendshme 27°CDB, 19°CWB; temp. e jashtme 35°CDB, 24°CWB | (3) - Ftohje: temp. e brendshme 27°CDB, 19°CWB; temp. e jashtme 35°CDB, 24°CWB | (3) - Ngrohje: temp. e brendshme 20°CDB; temp. e jashtme 7°CDB, 6°CWB | (3) - Ftohje: temp. e brendshme 27°CDB, 19°CWB; temp. e jashtme 35°CDB, 24°CWB | (3) - Ngrohje: temp. e brendshme 20°CDB; temp. e jashtme 7°CDB, 6°CWB | ||||
| (4) - Ngrohje: temp. e brendshme 20°CDB; temp. e jashtme 7°CDB, 6°CWB | (4) - Ftohje: temp. e brendshme 27°CDB, 19°CWB; temp. e jashtme 35°CDB, 24°CWB | (4) - Ftohje: temp. e brendshme 27°CDB, 19°CWB; temp. e jashtme 35°CDB, 24°CWB | (4) - Ngrohje: temp. e brendshme 20°CDB; temp. e jashtme 7°CDB, 6°CWB | (4) - Ftohje: temp. e brendshme 27°CDB, 19°CWB; temp. e jashtme 35°CDB, 24°CWB | (4) - Ngrohje: temp. e brendshme 20°CDB; temp. e jashtme 7°CDB, 6°CWB | ||||
| (5) - 220V | (5) - Ngrohje: temp. e brendshme 20°CDB; temp. e jashtme 7°CDB, 6°CWB | (5) - Ngrohje: temp. e brendshme 20°CDB; temp. e jashtme 7°CDB, 6°CWB | (5) - 220V | (5) - Ngrohje: temp. e brendshme 20°CDB; temp. e jashtme 7°CDB, 6°CWB | (5) - 220V | ||||
| (6) - 230V | (6) - Ngrohje: temp. e brendshme 20°CDB; temp. e jashtme 7°CDB, 6°CWB | (6) - Ngrohje: temp. e brendshme 20°CDB; temp. e jashtme 7°CDB, 6°CWB | (6) - 230V | (6) - Ngrohje: temp. e brendshme 20°CDB; temp. e jashtme 7°CDB, 6°CWB | (6) - 230V | ||||
| (7) - 240V | (7) - 220V | (7) - 220V | (7) - 240V | (7) - 220V | (7) - 240V | ||||
| (8) - Kur lidhet me njësinë e jashtme të sistemeve të shumëfishta, referohuni specifikimeve të njësisë së jashtme të shumëfishtë për t'u lidhur. | (8) - 230V | (8) - 230V | (8) - Kur lidhet me njësinë e jashtme të sistemeve të shumëfishta, referohuni specifikimeve të njësisë së jashtme të shumëfishtë për t'u lidhur. | (8) - 230V | (8) - Kur lidhet me njësinë e jashtme të sistemeve të shumëfishta, referohuni specifikimeve të njësisë së jashtme të shumëfishtë për t'u lidhur. | ||||
| (9) - Efikasiteti nominal: ftohje në ngarkesë nominale 35°/27°, ngrohje në ngarkesë nominale 7°/20° | (9) - 240V | (9) - 240V | (9) - Efikasiteti nominal: ftohje në ngarkesë nominale 35°/27°, ngrohje në ngarkesë nominale 7°/20° | (9) - 240V | (9) - Efikasiteti nominal: ftohje në ngarkesë nominale 35°/27°, ngrohje në ngarkesë nominale 7°/20° | ||||
| (10) - Kur lidhet me njësinë e jashtme të sistemeve të shumëfishta, referohuni specifikimeve të njësisë së jashtme të shumëfishtë për t'u lidhur. | (10) - Kur lidhet me njësinë e jashtme të sistemeve të shumëfishta, referohuni specifikimeve të njësisë së jashtme të shumëfishtë për t'u lidhur. | (10) - Kur lidhet me njësinë e jashtme të sistemeve të shumëfishta, referohuni specifikimeve të njësisë së jashtme të shumëfishtë për t'u lidhur. | |||||||
| (11) - Efikasiteti nominal: ftohje në ngarkesë nominale 35°/27°, ngrohje në ngarkesë nominale 7°/20° | (11) - Efikasiteti nominal: ftohje në ngarkesë nominale 35°/27°, ngrohje në ngarkesë nominale 7°/20° | (11) - Efikasiteti nominal: ftohje në ngarkesë nominale 35°/27°, ngrohje në ngarkesë nominale 7°/20° | |||||||