Tabela e specifikimeve për ETVH16E6V7 / EPRA14-18DW7

ETVH16S18EJ6V7 / EPRA14DAW17 ETVH16S23EJ6V7 / EPRA14DAW17 ETVH16S23EA6V7 / EPRA14DAW17 ETVH16S18EA6V7 / EPRA14DAW17 ETVH16S18EJ6V7 / EPRA14DBW17 ETVH16S18EA6V7 / EPRA14DBW17 ETVH16S23EA6V7 / EPRA14DBW17 ETVH16S23EJ6V7 / EPRA14DBW17 ETVH16S18EJ6V7 / EPRA16DAW17 ETVH16S23EJ6V7 / EPRA16DAW17 ETVH16S23EA6V7 / EPRA16DAW17 ETVH16S18EA6V7 / EPRA16DAW17 ETVH16S18EJ6V7 / EPRA16DBW17 ETVH16S18EA6V7 / EPRA16DBW17 ETVH16S23EA6V7 / EPRA16DBW17 ETVH16S23EJ6V7 / EPRA16DBW17 ETVH16S18EJ6V7 / EPRA18DAW17 ETVH16S23EJ6V7 / EPRA18DAW17 ETVH16S18EA6V7 / EPRA18DAW17 ETVH16S23EA6V7 / EPRA18DAW17 ETVH16S18EA6V7 / EPRA18DBW17 ETVH16S18EJ6V7 / EPRA18DBW17 ETVH16S23EA6V7 / EPRA18DBW17 ETVH16S23EJ6V7 / EPRA18DBW17
Kapaciteti ngrohës Min. kW 3.70 3.70 3.70 3.70 3.70 3.70 3.70 3.70 3.96 3.96 3.96 3.96 3.96 3.96 3.96 3.96 4.40 4.40 4.40 4.40 4.40 4.40 4.40 4.40
  Nom. kW 5.90 5.90 5.90 5.90 5.90 5.90 5.90 5.90 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00
  Maks. kW 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75 10.44 10.44 10.44 10.44 10.44 10.44 10.44 10.44 11.60 11.60 11.60 11.60 11.60 11.60 11.60 11.60
Fuqia në hyrje Ngrohje Min. kW 0.84 0.84 0.84 0.84 0.84 0.84 0.84 0.84 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
    Nom. kW 1.23 1.23 1.23 1.23 1.23 1.23 1.23 1.23 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80 1.80
    Maks. kW 2.17 2.17 2.17 2.17 2.17 2.17 2.17 2.17 2.32 2.32 2.32 2.32 2.32 2.32 2.32 2.32 2.58 2.58 2.58 2.58 2.58 2.58 2.58 2.58
  Uji i ngrohtë shtëpiak nga 10°C në 50°C Nom. kWh 2.57 2.85 2.85 2.57 2.57 2.57 2.85 2.85 2.57 2.85 2.85 2.57 2.57 2.57 2.85 2.85 2.57 2.85 2.57 2.85 2.57 2.57 2.85 2.85
Koha e ngrohjes nga 10°C në 50°C hr 9 orë 20 min. në temperaturë ambienti 7°C 1 orë 13 min. në temperaturë ambienti 7°C 1 orë 13 min. në temperaturë ambienti 7°C 9 orë 20 min. në temperaturë ambienti 7°C 9 orë 20 min. në temperaturë ambienti 7°C 9 orë 20 min. në temperaturë ambienti 7°C 1 orë 13 min. në temperaturë ambienti 7°C 1 orë 13 min. në temperaturë ambienti 7°C 9 orë 20 min. në temperaturë ambienti 7°C 1 orë 13 min. në temperaturë ambienti 7°C 1 orë 13 min. në temperaturë ambienti 7°C 9 orë 20 min. në temperaturë ambienti 7°C 9 orë 20 min. në temperaturë ambienti 7°C 9 orë 20 min. në temperaturë ambienti 7°C 1 orë 13 min. në temperaturë ambienti 7°C 1 orë 13 min. në temperaturë ambienti 7°C 9 orë 20 min. në temperaturë ambienti 7°C 1 orë 13 min. në temperaturë ambienti 7°C 9 orë 20 min. në temperaturë ambienti 7°C 1 orë 13 min. në temperaturë ambienti 7°C 9 orë 20 min. në temperaturë ambienti 7°C 9 orë 20 min. në temperaturë ambienti 7°C 1 orë 13 min. në temperaturë ambienti 7°C 1 orë 13 min. në temperaturë ambienti 7°C
COP 4.79 4.79 4.79 4.79 4.79 4.79 4.79 4.79 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00
Ngrohje uji të ngrohtë shtëpiak Të përgjithshme Profili i deklaruar i ngarkesës   L XL XL L L L XL XL L XL XL L L L XL XL L XL L XL L L XL XL
  Klimë mesatare Kategoria e efikasitetit të energjisë të ngrohjes së ujit   A A A A A A A A A A A A A A A A A A A A A A A A
Ngrohja e ambientit Dalja e ujit për klimë mesatare 55°C Të përgjithshme SCOP   3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57 3.57
  Dalja e ujit klimë mesatare 55°C Të përgjithshme Klas. efikasitetit të ngrohjes sezonale të ambientit   A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++
  Dalja e ujit për klimë mesatare 35°C Të përgjithshme SCOP   4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71 4.71
  Dalja e ujit klimë mesatare 35°C Të përgjithshme Klas. efikasitetit të ngrohjes sezonale të ambientit   A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
Shënime (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C (1) - Kapaciteti sipas standardit EN14511 dhe i vlefshëm për gamën e ujit të ngrohur dT = 3~8°C në Ta 7°C
  (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511 (3) - Fuqia në hyrje është totali i hyrjes së njësive të brendshme dhe të jashtme, duke përfshirë pompën e qarkullimit; sipas EN14511
  (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147. (4) - Testimi në Ta DB/WB 7°C/6°C. Sipas EN 16147.
  (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) me pompë në shpejtësi të plotë