| EWYA004D2V3P-H | EWYA006D2V3P-H | EWYA008D2V3P-H | EWYA009DAV3P-H- | EWYA011DAV3P-H- | EWYA014DAV3P-H- | EWYA016DAV3P-H- | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Kapaciteti ftohës | Nom. | kW | 4.86 (1), 4.52 (2) | 5.83 (1), 5.09 (2) | 6.18 (1), 5.44 (2) | 9.35 (1), 9.10 (2) | 11.6 (1), 11.5 (2) | 12.8 (1), 12.7 (2) | 14.0 (1), 15.3 (2) | ||
| Kontrolli i kapacitetit | Metoda | E ndryshueshme (inverter) | E ndryshueshme (inverter) | E ndryshueshme (inverter) | E ndryshueshme (inverter) | E ndryshueshme (inverter) | E ndryshueshme (inverter) | E ndryshueshme (inverter) | |||
| Fuqia në hyrje | Ftohje | Nom. | kW | 0.820 (1), 1.36 (2) | 1.08 (1), 1.55 (2) | 1.19 (1), 1.73 (2) | 2.79 (1), 1.71 (2) | 3.56 (1), 2.17 (2) | 4.06 (1), 2.51 (2) | 4.58 (1), 3.24 (2) | |
| EER | 5.91 (1), 3.32 (2) | 5.40 (1), 3.28 (2) | 5.19 (1), 3.14 (2) | 3.35 (1), 5.34 (2) | 3.26 (1), 5.31 (2) | 3.16 (1), 5.04 (2) | 3.06 (1), 4.74 (2) | ||||
| SEER | 5.62 (5) | 5.79 (5) | 5.71 (5) | 5.59 (5) | |||||||
| Dimensionet | Njësia | Thellësia | mm | 362 | 362 | 362 | 460 | 460 | 460 | 460 | |
| Lartësia | mm | 770 | 770 | 770 | 870 | 870 | 870 | 870 | |||
| Gjerësia | mm | 1250 | 1250 | 1250 | 1380 | 1380 | 1380 | 1380 | |||
| Pesha | Njësia | kg | 88 | 88 | 88 | 147 | 147 | 147 | 147 | ||
| Veshja e jashtme | Ngjyra | E bardhë fildishi | E bardhë fildishi | E bardhë fildishi | E bardhë fildishi | E bardhë fildishi | E bardhë fildishi | E bardhë fildishi | |||
| Materiali | Çelik me pak karbon, i veshur me zink | Çelik me pak karbon, i veshur me zink | Çelik me pak karbon, i veshur me zink | Pllakë çeliku e galvanizuar e veshur me poliestër | Pllakë çeliku e galvanizuar e veshur me poliestër | Pllakë çeliku e galvanizuar e veshur me poliestër | Pllakë çeliku e galvanizuar e veshur me poliestër | ||||
| Shkëmbyesi i nxehtësisë së ajrit | Lloji | Fletë me efikasitet të lartë dhe lloji i tubit me nën-ngrohës të integruar | Fletë me efikasitet të lartë dhe lloji i tubit me nën-ngrohës të integruar | Fletë me efikasitet të lartë dhe lloji i tubit me nën-ngrohës të integruar | Fletë me efikasitet të lartë dhe lloji i tubit me nën-ngrohës të integruar | ||||||
| Ventilatori | Sasia | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||
| Lloji | Ventilatori i helikës | Ventilatori i helikës | Ventilatori i helikës | Ventilatori i helikës | Ventilatori i helikës | Ventilatori i helikës | Ventilatori i helikës | ||||
| Motori i ventilatorit | Transmetimi | Transmetim direkt | Transmetim direkt | Transmetim direkt | Transmetim direkt | ||||||
| Kompresori | Sasia | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||
| Kompresori | Lloji | Kompresor rrotullues i mbyllur hermetikisht | Kompresor rrotullues i mbyllur hermetikisht | Kompresor rrotullues i mbyllur hermetikisht | Kompresor rrotullues inverter i mbyllur hermetikisht | Kompresor rrotullues inverter i mbyllur hermetikisht | Kompresor rrotullues inverter i mbyllur hermetikisht | Kompresor rrotullues inverter i mbyllur hermetikisht | |||
| Kompresori | Metoda e nisjes_ | Drejtuar me inverter | Drejtuar me inverter | Drejtuar me inverter | Drejtuar me inverter | ||||||
| Diapazoni i funksionimit | Ana e ajrit | Ftohje | Min. | °CDB | 10 (3) | 10 (3) | 10 (3) | 10 | 10 | 10 | 10 |
| Maks. | °CDB | 43 | 43 | 43 | 43 | 43 | 43 | 43 | |||
| Gama e funksionimit | Ana e ujit | Avulluesi | Min. | °CDB | 5 (3) | 5 (3) | 5 (3) | 5 | 5 | 5 | 5 |
| Maks. | °CDB | 22 | 22 | 22 | 22 | 22 | 22 | 22 | |||
| Niveli i fuqisë së zhurmës | Ftohje | Nom. | dBA | 61 | 62 | 62 | 65.5 | 67.0 | 69.0 | 69.0 | |
| Niveli i presionit të zhurmës | Ftohje | Nom. | dBA | 48 | 49 | 50 | 44.0 | 47.7 | 50.8 | 51.0 | |
| Agjenti ftohës | Lloji | R-32 | R-32 | R-32 | R-32 | R-32 | R-32 | R-32 | |||
| GWP | 675 | 675 | 675 | 675.0 | 675.0 | 675.0 | 675.0 | ||||
| Mbushja | kg | 1.35 | 1.35 | 1.35 | |||||||
| Qarqet | Sasia | 1 | 1 | 1 | 1 | ||||||
| Furnizimi me energji | Faza | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | |||
| Frekuenca | Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |||
| Tensioni | V | 230 +/-10% | 230 +/-10% | 230 +/-10% | 230 | 230 | 230 | 230 | |||
| Diapazoni i tensionit | Min. | % | -10 | -10 | -10 | -10 | |||||
| Maks. | % | 10 | 10 | 10 | 10 | ||||||
| Njësia | Rryma e punës | Maks | A | 30.8 | 30.8 | 30.8 | 30.8 | ||||
| Shënime | (1) - Kushti 1: ftohje Ta 35°C - LWE 18℃ (DT = 5°C); ngrohje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Kushti 1: ftohje Ta 35°C - LWE 18℃ (DT = 5°C); ngrohje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Kushti 1: ftohje Ta 35°C - LWE 18℃ (DT = 5°C); ngrohje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB | (1) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB | (1) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB | (1) - Ftohje: EW 12°C; LW 7°C; kushtet e ambientit: 35°CDB | ||||
| (2) - Kushti 2: ftohje Ta 35°C - LWE 7℃ (DT = 5°C); ngrohje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Kushti 2: ftohje Ta 35°C - LWE 7℃ (DT = 5°C); ngrohje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Kushti 2: ftohje Ta 35°C - LWE 7℃ (DT = 5°C); ngrohje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB | (2) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB | (2) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB | (2) - Ftohje: EW 23℃; LW 18℃; kushtet e ambientit: 35°CDB | |||||
| (3) - Për më shumë detaje, shihni skicën e diapazonit të funksionimit | (3) - Për më shumë detaje, shihni skicën e diapazonit të funksionimit | (3) - Për më shumë detaje, shihni skicën e diapazonit të funksionimit | (3) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (3) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (3) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (3) - Kushti: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | |||||
| (4) - Kushti: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (4) - Kushti: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (4) - Kushti: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (4) - Kushti: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | ||||||||
| (5) - Sipas EN14825 | (5) - Sipas EN14825 | (5) - Sipas EN14825 | (5) - Sipas EN14825 | ||||||||
| (6) - Në varësi të regjimit të përdorimit, referojuni manualit të instalimit. | (6) - Në varësi të regjimit të përdorimit, referojuni manualit të instalimit. | (6) - Në varësi të regjimit të përdorimit, referojuni manualit të instalimit. | (6) - Në varësi të regjimit të përdorimit, referojuni manualit të instalimit. | ||||||||
| (7) - Për më shumë detaje, shihni skicën e diapazonit të funksionimit | (7) - Për më shumë detaje, shihni skicën e diapazonit të funksionimit | (7) - Për më shumë detaje, shihni skicën e diapazonit të funksionimit | (7) - Për më shumë detaje, shihni skicën e diapazonit të funksionimit | ||||||||